Appendix D Synchronization Event Log Messages
D-5
Redline Communications Inc. Confidential and Proprietary
Slave
Synchronization Ok
Backup Detected
Master is offline, after rebooting.
Check the Master with GPS and
ensure it is online and that the GPS
is connected to the Master’s Sync In
port.
Verify that the synchronization
cables from the Master with GPS
and/or the Backup Master are
correctly connected to the Slaves’
Sync Out port.
Master
GPS is not Detected on the Master
No connection between the GPS and Master with GPS and the
Backup Master on Sync In or Sync Out port.
No corresponding event log messages are displayed by the Slave
devices.
Check the wiring connections
between Master with GPS and
Backup Master, check the
connection to the GPS unit.
Backup Master
Backup Function Activated
Master is not Detected
No connection between the GPS and Master with GPS and the
Backup Master on Sync In or Sync Out port.
You should see the above-listed messages on the Master.
No corresponding event log messages are displayed by the Slave
devices.
Check the wiring connections
between Master with GPS and the
Backup Master.
Also check the connections to the
GPS unit.
Master
GPS is not Detected
No connection between the GPS and the Master with GPS and
between the Master with GPS and Backup Master on the Sync In
port.
No corresponding event log messages are displayed by the Slave
devices.
Check the wiring connections
between the Master with GPS amd
the Backup Master.
Check the connection to the GPS
unit.
Table D-1
AN100U/UX Synchronization Event Log Messages (continued)
Message Reported
By
Event Log Message
(Logged starting from bottom to top)
Probable Cause
Recommended Troubleshooting