B-16
Redline Management Suite Administration and Maintenance Guide
Redline Communications Inc. Confidential and Proprietary
Master Function Activated
This AN100U/UX is configured as
Master, and it has successfully
activated.
Information only. There is no action required.
Master or GPS must be
connected. Waiting...
A Backup Master or Slave has not
detected the presence of a Master
with GPS or GPS clock source at the
Synch In port, at startup.
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Master with GPS Function
Activated
This AN100U/UX is configured as
Master, and has been successfully
activated.
Information only. There is no action required.
Other Backup Detected.
Waiting...
The AN100U/UX configured as a
Backup Master has detected another
backup device connected to Synch
Out port.
Only one Backup Master may be configured per
base station. You must configure one of the two
devices as a Slave.
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Other Master Detected.
Waiting...
The AN100U/UX configured to act as
a Master or a Master with GPS has
detected another Master connected to
Synch Out port.
Only one Master may be configured per base
station. Set one of the two AN100U/UX’s to act
either as a Slave, or Backup Master
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Reference Clock Calibration
Done
The reference clock calibration
procedure initiated by the user has
been completed.
Information only. There is no action required.
Synchronization Failed.
Waiting for Synchronization
Signal...
A sector controller configured as a
Slave has detected the Master or
Master with GPS on start up, but
synchronization failed. It will wait and
try again.
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Synchronization Ok
Synchronization with the Master or
Backup Master was successful.
Information only. There is no action required.
Synchronization Signal
Detected
A Slave has detected the clock signal
of from the Master or Backup Master.
Information only. There is no action required.
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment