Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
827
User Manual 1178.8520.02 ─ 01
................................................................................... 828
[SENSe:]LIST:RANGe<ri>:DETector
.................................................................................828
[SENSe:]LIST:RANGe<ri>:FILTer:TYPE
............................................................................829
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation
................................................................... 829
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation:AUTO
......................................................... 829
[SENSe:]LIST:RANGe<ri>:INPut:GAIN:STATe
...................................................................830
[SENSe:]LIST:RANGe<ri>:INPut:GAIN[:VALue]
.................................................................830
[SENSe:]LIST:RANGe<ri>:LIMit:STARt
.............................................................................830
[SENSe:]LIST:RANGe<ri>:LIMit:STATe
.............................................................................830
[SENSe:]LIST:RANGe<ri>:LIMit:STOP
............................................................................. 831
[SENSe:]LIST:RANGe<ri>:POINts[:VALue]
....................................................................... 831
................................................................................... 831
[SENSe:]LIST:RANGe<ri>:SWEep:TIME
.......................................................................... 831
[SENSe:]LIST:RANGe<ri>:SWEep:TIME:AUTO
................................................................ 832
[SENSe:]LIST:RANGe<ri>:TRANsducer
........................................................................... 832
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution
<RBW>
This command defines the resolution bandwidth for a spurious emission measurement
range.
Suffix:
<ri>
.
1..n
Selects the measurement range.
Parameters:
<RBW>
Resolution bandwidth.
Refer to the data sheet for available resolution bandwidths.
Default unit: Hz
Manual operation:
See
[SENSe:]LIST:RANGe<ri>:BANDwidth:VIDeo
<VBW>
This command defines the video bandwidth for a spurious emission measurement
range.
Suffix:
<ri>
.
1..n
Selects the measurement range.
Parameters:
<VBW>
Video bandwidth.
Refer to the data sheet for available video bandwidths.
Default unit: Hz
Manual operation:
See
[SENSe:]LIST:RANGe<ri>:BREak
<State>
This command controls the sweep (for all ranges, <range> is irrelevant).
Configuring and Performing Measurements