Analog Demodulation Option R&S
FSV–K7
R&S
®
FSV-K7/K7S
70
Operating Manual 1176.7561.02 ─ 06
Remote command:
Marker Table
Defines how the marker information is displayed.
For more information, see "Displayed Marker Information" in the description of the
base unit.
"On"
Displays the marker information in a table in a separate area beneath
the diagram.
"Off"
Displays the marker information within the diagram area.
"Aut"
(Default) The marker table is displayed automatically if more than 2
markers are active, and removed if only 1 or 2 markers are active.
This helps keep the information in the display clear.
Remote command:
Marker Stepsize
Opens a submenu to set the step size of all markers and delta markers.
Default value for the marker step size is
.
Stepsize Standard ← Marker Stepsize
Moves the marker or delta marker from one measurement point to the next, if the
marker or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 /
Marker 3 / … Marker 16,/ Marker Norm/Delta" softkeys, see
Marker 3 / … Marker 16,/ Marker Norm/Delta"
on page 68). If more measured values
than measurement points exist, it is not possible to read out all measured values. In
this case, use the
softkey.
Remote command:
CALC:MARK:X:SSIZ STAN
(see
CALCulate<n>:MARKer<m>:X:SSIZe
Stepsize Sweep Points ← Marker Stepsize
Moves the marker or delta marker from one measured value to the next, if the marker
or delta marker value is changed via the rotary knob ( "Marker 1 / Marker 2 / Marker 3 /
… Marker 16,/ Marker Norm/Delta" softkeys, see
"Marker 1 / Marker 2 / Marker 3 / …
Marker 16,/ Marker Norm/Delta"
on page 68). If more measured values than measure-
ment points exist, every single measured value is accessible and its value is displayed
in the marker field.
The number of measured values is defined in the ""Sweep"" menu via the
This functionality is available for all base unit measurements with the exception of sta-
tistics ( "APD" and "CCDF" softkeys in the "Measurement" menu).
Remote command:
CALC:MARK:X:SSIZ POIN
(see
CALCulate<n>:MARKer<m>:X:SSIZe
Softkeys of the Analog Demodulation option