Analog Demodulation Option R&S
FSV–K7
R&S
®
FSV-K7/K7S
162
Operating Manual 1176.7561.02 ─ 06
4: the following number of data bytes has 4 digits
1024: 1024 Bytes of following data; float: 4 Bytes / value => 1024 / 4 = 256 values (128
I and 128 Q values)
<value x>: 4 Byte values, must be interpreted as float
For
≧
10
10
samples:
The schema of the result string is as follows:
#(<NoOfDataBytes>)<value1><value2>…<value n>
, with
#
Header prefix, 1 byte
(
1 byte
<NoOfDataBytes>
number of following data bytes (= 1024 in the example), 10 bytes
)
1 byte
<Value>
Data values, each one is a 4-byte floating point value
Example:
#(1677721600)<value 1><value 2> ... <value 419430400>
(1677721600): 1677721600 Bytes of following data; float: 4 Bytes / value ==>
1677721600/ 4 = 419430400 values (200Ms I and 200Ms Q values)
<value x>: 4 Byte values, must be interpreted as float
2.3.8
TRIGger Subsystem (Analog Demodulation, R&S
FSV–K7)
The TRIGger subsystem is used to synchronize instrument actions with events. It is
thus possible to control and synchronize the start of a sweep.
TRIGger<n>[:SEQuence]:BBPower:HOLDoff
.................................................................... 163
TRIGger<n>[:SEQuence]:HOLDoff[:TIME]
........................................................................ 163
TRIGger<n>[:SEQuence]:IFPower:HOLDoff
..................................................................... 163
TRIGger<n>[:SEQuence]:IFPower:HYSTeresis
................................................................. 164
TRIGger<n>[:SEQuence]:LEVel:AM[:ABSolute]
.................................................................164
TRIGger<n>[:SEQuence]:LEVel:AM:RELative
...................................................................164
TRIGger<n>[:SEQuence]:LEVel:BBPower
........................................................................ 165
TRIGger<n>[:SEQuence]:LEVel:FM
.................................................................................165
TRIGger<n>[:SEQuence]:LEVel:IFPower
..........................................................................165
TRIGger<n>[:SEQuence]:LEVel:RFPower
........................................................................ 166
TRIGger<n>[:SEQuence]:LEVel:PM
.................................................................................166
TRIGger<n>[:SEQuence]:TIME:RINTerval
........................................................................ 166
TRIGger<n>[:SEQuence]:LEVel:VIDeo
.............................................................................167
.....................................................................................167
.................................................................................. 167
Remote Commands of the Analog Demodulation (R&S
FSV–K7)