[SENSe:]FREQuency:CENTer:STEP:LINK:FACTor
<Factor>
This command defines a step size factor if the center frequency step size is coupled to
the span or the resolution bandwidth.
Parameters:
<Factor>
Range:
1 to 100
*RST:
10
Default unit: PCT
Example:
FREQ:CENT:STEP:LINK:FACT 20PCT
Manual operation:
See
See
"0.1*Demod BW (AF/RF Time Domain, AF Spectrum)"
on page 41
See
See
"0.5*Demod BW (AF/RF Time Domain, AF Spectrum)"
on page 41
See
See
"x*Demod BW (AF/RF Time Domain, AF Spectrum)"
2.3.6.8
SENSe:SWEep Subsystem (Analog Demodulation, R&S
FSV–K7)
The SENSe:SWEep subsystem controls the sweep parameters.
.................................................................................................155
....................................................................................156
....................................................................................156
................................................................................... 156
........................................................................................156
.................................................................................................157
[SENSe:]SWEep:COUNt
<NumberSweeps>
This command defines the number of sweeps started with single sweep, which are
used for calculating the average or maximum value. If the values 0 or 1 are set, one
sweep is performed.
Parameters:
<NumberSweeps>
0 to 32767
*RST:
0 (GSM: 200, PHN:1)
Example:
SWE:COUN 64
Sets the number of sweeps to 64.
INIT:CONT OFF
Switches to single sweep mode.
INIT;*WAI
Starts a sweep and waits for its end.