Analog Demodulation Option R&S
FSV–K7
R&S
®
FSV-K7/K7S
124
Operating Manual 1176.7561.02 ─ 06
Example:
ADEM ON
, see
Switches on the analog demodulator
CALC:FEED 'XTIM:FM:AFSP'
, see
on page 90
Switches on AF spectrum result display of FM
ADEM:BAND 5 MHz
, see
Sets the measurement bandwidth to 5 MHz
ADEM:AF:STAR 0 kHz
Sets the AF start frequency to 0 kHz
Sets the AF stop frequency to 500 kHz
Mode:
ADEMOD
Manual operation:
See
[SENSe:]ADEMod<n>:AF:STOP
<Frequency>
This command sets the stop frequency for AF spectrum result display.
The stop frequency is limited to half the measurement bandwidth of analog demodula-
tion (
[SENSe:]ADEMod:BANDwidth|BWIDth:DEModulation
Suffix:
<n>
.
1...4
irrelevant
Parameters:
<Frequency>
*RST:
2.5 MHz
Example:
ADEM ON
, see
Switches on the analog demodulator
CALC:FEED 'XTIM:FM:AFSP'
, see
on page 90
Switches on AF spectrum result display of FM
ADEM:BAND 5 MHz
, see
Sets the measurement bandwidth to 5 MHz
Sets the AF start frequency to 0 kHz
ADEM:AF:STOP 500 kHz
Sets the AF stop frequency to 500 kHz
Mode:
ADEMOD
Manual operation:
See
Remote Commands of the Analog Demodulation (R&S
FSV–K7)