Example:
ADEM ON
, see
Switches on analog demodulator
CALC:FEED 'XTIM:AM:TDOM'
, see
on page 90
Switches on AM result display.
DISP:TRAC ON
, see
DISPlay[:WINDow<n>]:TRACe<t>[:
Switches the trace on.
CALC:MARK:FUNC:ADEM:AFR?
Queries the audio frequency.
Usage:
Query only
Mode:
ADEMOD
CALCulate<n>:MARKer:FUNCtion:ADEMod:AM[:RESult<t>]?
<Result>
CALCulate<n>:MARKer:FUNCtion:ADEMod:AM[:RESult<t>]??
<MeasType>
This command queries the results of the AM modulation measurement.
Suffix:
<n>
.
1...4
irrelevant
<t>
1...6
trace 1, 2, 3, 4, 5 or 6
Parameters:
<Result>
The result of the selected measurement type is returned.
Query parameters:
<MeasType>
PPEak | MPEak | MIDDle | RMS
PPEak
Measurement with detector Pluspeak (+PK)
MPEak
Measurement with detector MinusPeak (-PK)
MIDDle
Averaging ±PK/2
RMS
RMS measurement
Example:
ADEM ON
Switches on the analog demodulator.
CALC:FEED 'XTIM:AM:TDOM'
, see
on page 90
Switches on the AM result display.
DISP:TRAC ON
, see
DISPlay[:WINDow<n>]:TRACe<t>[:
Switches on the trace.
CALC:MARK:FUNC:ADEM:AM? PPE
Queries the peak value.
Remote Commands of the Analog Demodulation (R&S