Analog Demodulation Option R&S
FSV–K7
R&S
®
FSV-K7/K7S
170
Operating Manual 1176.7561.02 ─ 06
Parameters:
<Unit>
DBM | V | A | W | DBPW | WATT | DBUV | DBMV | VOLT |
DBUA | AMPere
*RST:
dBm
Example:
UNIT:POW DBM
Sets the power unit to dBm.
Mode:
A, ADEMOD, SFM, SPECM
UNIT:THD
<Mode>
Selects the unit for THD measurements.
Parameters:
<Mode>
DB | PCT
*RST:
DB
Example:
UNIT:THD PCT
Mode:
ADEMOD, SFM
Manual operation:
See
See
2.3.10
Other Commands Referenced in this Manual
2.3.10.1
CALCulate:DELTamarker Subsystem (Analog Demodulation, R&S
FSV–K7)
The CALCulate:DELTamarker subsystem controls the delta marker functions of the
instrument.
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:MAXimum[:PEAK]
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X
............................................. 171
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:Y
............................................. 171
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed[:STATe]
............................................... 172
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise[:STATe]
............................................. 172
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:AUTO
............................................... 173
CALCulate<n>:DELTamarker<m>:LINK
............................................................................ 173
CALCulate<n>:DELTamarker<m>:MREF
.......................................................................... 174
CALCulate<n>:DELTamarker<m>[:STATe]
........................................................................ 174
CALCulate<n>:DELTamarker<m>:TRACe
.........................................................................174
................................................................................. 175
CALCulate<n>:DELTamarker<m>:X:RELative?
................................................................. 175
CALCulate<n>:DELTamarker<m>:Y?
............................................................................... 176
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:MAXimum[:PEAK]
This command moves the fixed reference marker to the peak power.
Remote Commands of the Analog Demodulation (R&S
FSV–K7)