SNC 4000 User’s Guide
85
gateAddrGet
The
gateAddrGet
command displays the default network gateway address if one has been set. This
address is used when connections are made to a different subnet and there are no explicit routes defined
for that subnet. Consult your network administrator for more information on the default gateway (sometimes
referred to as default router) address
.
SNC4000 > gateAddrGet
Gateway Address set to 192.168.1.1
value = 0 = 0x0
gateAddrSet
The
gateAddrSet
command changes the default network gateway address. This address is used when
connections are made to a different subnet and there are no explicit routes defined for that subnet. Consult
your network administrator for more information on the default gateway (sometimes referred to as default
router) address
.
Successful
gateAddrSet
:
SNC4000 > gateAddrSet "10.0.0.1"
value = 0 = 0x0
Failed
gateAddrSet
(1):
The following message is received when trying to set a new gateway address and that address is currently
unreachable. The following message is sent to the terminal.
SNC4000 > gateAddrSet "10.0.0.1"
gateAddrSet: Error setting current gate addr: S_errno_ENETUNREACH
value = -1 = 0xffffffff = payloadCh 0xffd418a3
The new gateway address is written to the bootup parameters to be used at the next boot. If at next boot,
the address is reachable, then it will be written to the system file. If at next boot the gateway address is not
reachable and therefore not written to the system file, the following message is displayed:
Failed
gateAddrSet
(2):
SNC4000 > gateAddrSet "172.16.76.1"
gateAddrSet: Error deleting old gateway addr: S_errno_ESRCH
Gateway Address set to 172.16.76.1 for Ethernet interface
value = 0 = 0x0
ghostIOSet [ticks]
The
ghostIOSet
command changes the number of ticks that a command remains queued for
transmissions to the target. Each tick is 1/60th of a second. The number of ticks can be set from 1 to 60. If
ticks are set to 0, command queuing is disabled.
SNC > ghostIOSet 30
Ghost I/O support is enabled.
Stale commands will be deleted after 30 ticks (500 ms).
value = 30 = 0x1e
SNC >
Parameter
Value
Valid Range
Meaning
Ticks
1/60th of a second
0-60
Number of ticks commands remain
in queue
Содержание SNC 4000
Страница 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Страница 10: ...4 SNC 4000 Introduction...
Страница 40: ...34 Removal and Replacement Procedures...
Страница 140: ...134 Service Port Command Reference...
Страница 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Страница 148: ...142 Diagnostic Command Reference...