SNC 4000 User’s Guide
79
fcConnTypeGet [port]
The
fcConnTypeGet
command is used to display the current setting of a FC port’s connection type. See
also the
fcConnTypeSet
command.
The following example shows how the connection type is displayed when FC port 1 is specified and its
connection type is loop.
SNC4000 > fcConnTypeGet 1
value = 0 = 0x0
fcConnTypeSet [port],[connection]
The
fcConnTypeSet
command is used to set the type of connection for a FC port. See also the
fcConnTypeGet
command.
The following example shows how to set the FC port connection type to point-to-point.
SNC4000 > fcConnTypeSet 1,1
value = 0 = 0x0
fcFibreSpeedGet [port]
The
fcFibreSpeedGet
command displays the requested speed of the FC port. The actual speed can be
viewed in the output of the
fcShow
command. The example below shows that the FC port has a maximum
speed of 1 Gb/sec.
SNC4000 > fcFibreSpeedGet 1
value = 1= 0x1
Parameter
Value
Meaning
port
1
The SNC 4000 Connection labeled FC1
connection type
0
Loop
1
Point-to-point
2
Loop preferred
Parameter
Value
Meaning
Port
1
The SNC 4000 Connection labeled FC1
Connection Type
0
Loop
1
Point-to-Point
2
Loop Preferred
CAUTION
You must issue the
fcRestart
command or reboot the SNC 4000 for
the new setting to take effect. See the
fcRestart
command for
further information.
Parameter
Value
Meaning
port
1
The SNC 4000Connection labeled FC1
Содержание SNC 4000
Страница 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Страница 10: ...4 SNC 4000 Introduction...
Страница 40: ...34 Removal and Replacement Procedures...
Страница 140: ...134 Service Port Command Reference...
Страница 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Страница 148: ...142 Diagnostic Command Reference...