76
Service Port Command Reference
The SNC 4000 is addressable as a SCSI target device for command and control support. On a FC Interface,
this device will be seen as logical unit number 0, (LUN 0). The LUN 0 device returns a device type of 0Ch
in an inquiry command, indicating it is a controller device. Controller devices are defined in the SCSI-3
Controller Commands specification (SCC).
In some cases, it may be desirable to disable this feature. If LUN 0 is disabled, then a device type of 2Ch
will be returned in an inquiry to LUN 0, indicating that the device is not presently available at this LUN. LUN
0 will remain reserved for the Command and Control interface and will not be allocated to another target
device.
Other commands are available for re-enabling the Command and Control interface or reassigning it to a
different LUN rather than hiding or disabling it. See the
enableCC
command and the
setSnaCCLun
command for further information.
SNC4000 > disableCC
value = 0 = 0x0
SNC4000 >
enableCC
To restore the capability to send commands to the command and control interface (LUN 0), use the
enableCC
command. The command is typically used to re-enable the interface after it was disabled by the
disableCC
command.
SNC4000 > enableCC
value = 0 = 0x0
envMonShow
The
envMonShow
command lists all of the environmental channel states and their current values. Use the
command
envMonRangeShow
to restrict output to a display of the ranges relevant to each state. The
following channels have been defined:
SNC4000 > envMonShow
Description State Value
2
Completely disables all Command and Control functions
CAUTION
If you enter the
disableCC
command without specifying an option
number, it has the same effect as
disableCC 1
.
Channel Name
Description
Air Inlet Temp
Temperature of the air as it enters the unit
IO Processor Temperature
Temperature of the IO Processor
Input Power: +5 Volts
Voltage level of the
+
5 input
Input Power:
+
12 Volts
Voltage level of the
+
12 input
Local Power:
+
2.5 Volts
Voltage level of the local +2.5 supply
Local Power:
+
3.3 Volts
Voltage level of the local
+
3.3 supply
Fan
Fan running (for tachometer fans: RPM of fan)
Option
Number
Value
Содержание SNC 4000
Страница 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Страница 10: ...4 SNC 4000 Introduction...
Страница 40: ...34 Removal and Replacement Procedures...
Страница 140: ...134 Service Port Command Reference...
Страница 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Страница 148: ...142 Diagnostic Command Reference...