30
Removal and Replacement Procedures
Ethernet Test
For further information about the procedures and commands used in this section, see
Connecting to the
Service Port
on page 23 and
Diagnostic Command Reference
on page 135.
1
If you did not replace the SNC, go to
Step 4
.
2
Obtain the SNC’s Ethernet network parameters.
3
Configure the Ethernet port host name, address, routes, enable Ethernet. For more information, see
Network Setup for the SNC
on page 30.
4
Attach the Ethernet loop back plug to the Ethernet port.
5
From the service terminal, enter the
elTest
command.
6
If the test passes, go to
Step 7
. If the test does not pass, go to
Start MAP
on page 42.
7
Remove the Ethernet loop back plug.
8
Proceed to
Updating the SNC
on page 31.
Network Setup for the SNC
The SNC must be connected to a 10/100-base-T Ethernet network for use with the ADIC Management
Console software. An RJ-45 connector is located on the rear panel of the SNC for connection to the
Ethernet. See
Ethernet
on page 7. You will need to connect a terminal or terminal emulator to the service
port of the SNC in order to configure the IP address. For more information, see the
ADIC Management
Console User’s Guide
.
Figure 7
Ethernet Port
1
To configure the network, connect to the SNC service port. For more information, see
Connecting to the
Service Port
on page 23.
In all of the subsequent steps, substitute the values you configured during installation. For more
information on the commands used in this procedure, see
Commands Listed Alphabetically by Function
on page 63.
2
Enter the
hostNameSet
command to set the host name.
Содержание SNC 4000
Страница 1: ...www adic com ADICSNC 4000User sGuide ADVANCED DIGITAL INFORMATION CORPORATION...
Страница 10: ...4 SNC 4000 Introduction...
Страница 40: ...34 Removal and Replacement Procedures...
Страница 140: ...134 Service Port Command Reference...
Страница 147: ...SNC 4000 User s Guide 141 fcConnPortModeGet...
Страница 148: ...142 Diagnostic Command Reference...