When an error message is displayed (Error code list)
Maintenance/Troubleshooting
1-140
RAAA006 The project data
contains functions
that are not sup-
ported by this ver-
sion.
There are functions that cannot be
recognized by the runtime program.
The editor’s version and runtime’s
version may not match. Update the
runtime’s version.
—
RAAA007 The no. of parts in
the screen exceeds
the limit. (MAX 384)
There are more than 384 parts set on
a single screen.
The number of parts exceeds the
limit during a screen change or when
opening a window. Make sure to set
parts within the permitted range.
)
RAAA008 The font (XXXX)
does not exist.
(Transfer the font
with the project.)
The font you are trying to display
does not exist in the system. Down-
load the font into the system.
The following table shows the font
names.
)
GP-Pro EX Refer-
ence Manual “6.4
[Font] Settings
Guide” (page 6-
19)
RAAA010 The CF card has not
been inserted, or the
CF card hatch is
open.
The CF card cannot be accessed.
Check if the CF card is inserted or if
the CF hatch can close. Insert the CF
card and close the hatch.
)
GP3000 Series
Hardware Manual
Continued
Error No.
Error Message
Cause and Solution
Reference
English Standard
Japanese Standard
Korean Standard
Chinese Standard
Taiwanese Standard
English Stroke
Japanese Stroke
Korean Stroke
Chinese Stroke
Taiwanese Stroke