When an error message is displayed (Error code list)
Maintenance/Troubleshooting
1-138
*2
The setting range of the bit addresses to control whether to execute or to stop the com-
munication scan is the internal device address’ LS9550 to LS9557. Each device/ PLC
address starting from Bit 0 is assigned sequentially to each driver’s device/PLC starting
from the first unit.
e.g.)
You can set the bit addresses controlling the communication scan of the Driver 1’s first
to 16th units to LS9550.
[LS9550]
Bit 0: Scans ON/OFF the Driver 1’s first PLC.
Stops the scan (scans OFF) of the Driver 1’s first PLC by turning ON Bit 0. Turn OFF
Bit 0 to resume the scan.
You cannot stop the communication scan of a device specified with the System Area
Start Address. However, if you are not using the System Data Area, you can stop the
communication scan.
)
GP-Pro EX Reference Manual “5.14.6 [System Settings] Setting Guide u System Area Set-
• You can set the LS area’s addresses with 32 bits on some devices/PLCs. In this case,
the lower 16 bits are used for the bit addresses controlling the communication scan.
• When you turn OFF the communication scan, the displayed part’s data will remain.
However, if you change screens and then display the screen again, the part’s data will
not be displayed.
Driver 1's 1st to 16th units
Driver 1's 17th to 32nd units
Driver 2's 1st to 16th units
Driver 2's 17th to 32nd units
Driver 3's 1st to 16th units
Driver 3's 17th to 32nd units
Driver 4's 1st to 16th units
Driver 4's 17th to 32nd units
Reserved
Reserved
LS9550
LS9551
LS9552
LS9553
LS9554
LS9555
LS9556
LS9557
LS9558
LS9559
LS Area
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0