49
Parameter
Name /
Description
Range
Default
value
Function
Set on
RUN
4 DIGIT I MODE=1
G4.1.4
/
Selection of
Digital Inputs
configuration
0 – 5
1
It allows user to configure the digital inputs for different functions. All
the options described below will program to all the digital inputs
simultaneously, except for option '1
Î
All Programmable', which
allows to configure their in a separate way.
OPT
DESCRIPTION
FUNCTION
0 3
WIRES
'Start/Stop and Reset' by
terminals.
DI1 = 01
Î
Start (NO)
DI2 = 04
Î
Stop 1-Reset (NC)
DI3 = 03
Î
Stop 2-Reset (NC)
DI4 = 15
Î
Reference 2 (NO)
DI5 = 10
Î
Speed Inversion
(NC)
DI6 = 17
Î
Control 2 (NO)
1
ALL
PROGRAMMABLE
Inputs configuration individually
by user. See G4.1.5 to G4.1.10.
2
MREF 2 WIRES
Digital inputs 5 and 6 are
programmed as multiple
references (of speed or PID
references) for up to 4 preset
speeds. The remaining inputs
are user programmable.
PARM DI5 DI6
G14.4
0 0
G14.5
0 X
G14.6
X 0
G14.7
X X
Note:
It is necessary to set G3.1
REF1 SPD=MREF or G3.2 REF2
SPD=MREF.
3
MREF 3 WIRES
Digital inputs 4, 5 and 6 are
programmed as multiple
references (of speed or PID
references) for up to 7 preset
speeds. The remaining inputs
are user programmable.
PARM DI4 DI5 DI6
G14.1
0 0 X
G14.2
0 X 0
G14.3
0 X X
G14.4
X 0 0
G14.5
X 0 X
G14.6
X X 0
G14.7
X X X
Note:
It is necessary to set G3.1
REF1 SPD=MREF or G3.2 REF2
SPD=MREF.
Note:
See following page.