VISUALIZATION AND STATUS PARAMETERS. GROUP G0
41
9.2.
Parameters SV.2 – Drive Visualization
Screen
Units
Description
390 390 390V
V
It shows the input instantaneous voltage applied to the drive (RS, ST, RT).
Inp Vol = 390V
V
It shows the average input voltage to the drive.
50.0 50.0 50.0Hz
Hz
It shows the frequency of the input voltage to the drive.
Bus vol = 540V
Vdc
It shows DC Link voltage of the drive.
IGBT Temp =+23ºC
ºC
It shows the temperature measured at the power stage of the drive output.
Drive Temp =+26ºC
ºC
It shows the temperature measured inside the electronics chamber of the drive.
9.3.
Parameters SV.3 – External Visualization
Screen
Units
Description
ANLG IN1 = +0.0V
V or mA
It shows the value of Analogue Input 1.
AIN1 Refr = +0.00%
% bottom scale
AI1
It shows the value or the PID reference proportional to Analogue Input 1 in percentage.
AIN1 S = +0.00Bar
Engineering
units
It shows the value of sensor 1 associated to the Analogue Input 1.
ANLG IN2 = +0.0V
V or mA
It shows the value of the Analogue Input 2.
AIN2 Refr = +0.00%
% bottom scale
AI2
It shows the value or the PID reference proportional to the Analogue Input 2 signal.
AIN 2 S = +0.00Bar
Engineering
units
It shows the value of sensor 2 associated to the Analogue Input 2.
ANL OUT1 = +4.0mA
V or mA
It shows the value of Analogue Output 1.
AOUT1 Refer = +0.0%
% associated
magnitude
It shows the magnitude value associated to the Analogue Output 1 (speed, current ...).
ANL OUT2 = +4.0mA
V or mA
It shows the value of Analogue Output 2.
AOUT2 Refer = +0.0%
% associated
magnitude
It shows the magnitude value associated to the Analogue Output 2 (speed, current ...).
Input DG: 000000 0
-
It shows whether the Digital Inputs are activated or not, from DI1 to DI6. The final is another
input which shows the status of the motor PTC signal.
X: Active.
0: Not Active.
Relays: X 0 X
-
It shows whether the output relays are activated or not.
X: Active.
0: Not Active.
Speed M = +0.000m/s
Depending on
config.
It shows the speed of the motor in engineering units. Pressing
∗
key you can access to the
following sub-parameters of configuration:
Screen
Range
Description
Scale ftr=1
0.001 -
10
To set the ratio factor between motor speed and
machine speed.
Units Ma=m/s
m/s
m/m
cm/s
cm/m
v/s
v/m
It allows selection of the units to be displayed
Units Description
m/s
Meters / second
m/m
Meters / minute
cm/s
Centimetres / second
cm/m
Centimetres / minute
v/s
Turns / second
v/m
Turns / minute
Note:
They both are settable during run.