- 38 -
1900-EN Wartung_2723
MAINTENANCE
EN
Tine arms
Change tine arms
- Loosen cover bolts (1).
1
- 1. Remove 2x bolts M12x110 (2)
2. Loosen 4x bolts M12x110 (3).
3
2
- Remove cover
- Pull tine arm out. Turn the rotor unit so that the old
tine arm can be pulled out between the intake and
output (see below).
- Insert new tine arm. Turn the rotor unit so that the
new tine arm can be inserted between the intake
and output control (see below).
Direction of
travel
travel
- Re-tighten bolts M12x110 with 1x nut and 2x Nordlock
washers (see illus.)
(Tightening torque: 140 Nm)
Lay the Nordlock washers with rough internal milling
on top of one another. This means that both washers
have the fine milling outside.
- Attach cover to the new tine arm, fit it between the
covers and tighten the screw. Tighten all the loosened
bolts (1) for the covers.
- Check the tightness of the bolts and nuts after approx.
50 hours of operation and re-tighten if necessary.
- Pay attention to the position of the dowel pins in relation
to each other. see picture below - Detail B
B