Alcatel Vacuum Technology France - ATH 200 User’s Manual
Disconnecting the pump from the
installation
Turning off the pump
Turn off the pump, turn the main switch to “0”.
Turn off the customer’s main circuit breaker and lock out tag out per
customer facility procedures.
Disconnect the main power plug from the main power connector of the
pump
B 40
.
Disconnecting
the facilities
Disconnect the remote control connector (dry contacts /16 or 19 pin
plug).
Disconnect the water inlet and outlet quick connectors.
Disconnect the pump from the inlet piping.
Blank-off the equipment inlet piping.
Disconnect the pump from the exhaust piping.
Blank-off the equipment exhaust piping.
Disconnect the pump
from the installation
Remove the anti earthquake squares.
Raise the four legs.
Remove the pump from the installation.
Study the precautions for first use
D 00 and E 11
.