GB 02125 - Edition 05 - Dec 11
1/2
D 00
Alcatel Vacuum Technology France - ATH 200 User’s Manual
Safety instruction related to maintenance
This chapter describes the main preventive maintenance operations and
provides a guide for first diagnosis in the event of an accident.
Located on the cover of the pump, this label warns the user against
possible risk of injury due to any hand contact with hot surfaces.
It states that protective gloves should be used before performing any
intervention.
Located on the upper cover, this label indicates that some of the internal parts
are energized and could cause electrical shocks in case of contact. It advizes
to disconnect the pump before any intervention or to properly lock-out and
tag-out the equipment breaker before any intervention on the pump.
Maintenance must be performed by a skilled maintenance operator
trained in the relevant health and safety aspects (EMC, electrical hazards,
chemical pollution, etc.).
Electric shock hazard on touching.
When the main isolator is switched to the «0» position, items located
between the mains connection and the isolator are still under mains
voltage.
Disconnect the mains cable from all power sources before commencing any
maintenance work on the product.
Hazardous voltage enclosed.
Voltage or current hazard sufficient to cause shock.
Disconnect and lockout power before servicing.
Any intervention must be done by trained personnel only.
Electric shock hazard.
Some components have capacitors charged to over 60VDC. When power
is switched off, they keep their charge for a time. Residual voltages from
the filter capacitors can cause electric shocks all the way back to the mains
plug. Wait 5 minutes after power-off before commencing any work on the
product.
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions