Alcatel Vacuum Technology France - ATH 200 User’s Manual
Positioning the pump in the pumping
installation
GB 04168 - Edition 03 - November 11
Risk of tilting
Although the product meets EEC safety regulations (topple angle ± 10 °), it
is advisable to guard against the risk of tilting during handling, installation,
and use.
Refer to chapter A of the operating instruction manual for location of the
center of gravity.
Don’t place the product on a tilted surfaces, it can drag the operator along
due to its heavy weight:
- use castors to move it on short distances,
- locate it on flat, hard ground,
- do not push it sideways
- adjust the levelling feet for operation to make sure that the pump is not
supported by the castors.
The product is not designed to carry people or loads and is not for use as
a seat or step.
Lock the pump frame by adjusting the four levelling feet for resting solidly
on the floor. Use a water level to check if the pump is correctly positionned
in both axis.
Y
X
Level tool
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions