Alcatel Vacuum Technology France - ATH 200 User’s Manual
Diagnosis and trouble shooting
INCIDENT
CAUSE
TROUBLESHOOTING
The main switch is on position
«1»
The main switch is on position
«0»
Î
Set the main switch to position
1.
)
The switch is in «remote» mode
position.
Î
Check the presence of 15 or 24
VDC between the pins 1 and 2
of the J4 connector
G 10
.
Place the switch in «local» mode
C 10
.
)
)
Customer supply voltage different
from :
380/460 VAC (high voltage)
200/208 VAC (low voltage)
Î
Check the voltage of the
installation.
)
Other problem
Î
Call the customer service center.
)
Pump does not start and light indicators are not lit up
INCIDENT
CAUSE
TROUBLESHOOTING
Temperature problem
The motor temperature is
> 150°C
Î
Check the water supply.
Check that the water supply
temperature is < 25°C.
Check that the water cooling line
is not clogged or has no leaks.
)
)
)
The water temperature flow is
insufficient
Î
Check that the water flow is
> 100l/h.
)
Other problem
Î
Call the customer service center.
)
Pump does not start and red light indicator is lit up