Alcatel Vacuum Technology France - ATH 200 User’s Manual
Operating modes
Different control
modes
According to the monitoring configuration and wiring, the pump can
be:
Locally controlled by the main switch «Autostart».
Remote controlled by remote control (dry contacts / 16 or 19 pin
plug).
Local control mode
Starting mode via main
switch «Autostart»
The pump is running as a «stand-alone» part of the equipment on which
it has been installed.
The pump is controlled with the start and stop main switch.
Remote control mode
Starting mode via «remote
control (dry contacts / 16 or
19 pin plug)»
First, push the main switch to «1».
The pump is monitored by the equipment in which it is installed.
The pump is remote controlled by the opening or closing of different dry
contacts wired on remote control connector
B 60 or B 61
.
Selection of the pump
control mode
The selection of the pump control mode (local or remote) is performed
by the switch located at the pump front panel.
To change the «Local control mode» in «Remote control mode» or vice-
versa, adjust the switch position:
Loc-Rem
Loc-Rem
switch on the left = Local mode
switch on the right = Remote mode
Hazard - Red light
Warning - Yellow light
ON - Green light
Operating time meter
Local-Remote switch
Control
remote
Power start
Description
Local
Autostart
•
Start / Stop the pump:
through main switch
C 20
.
•
Remote
Remote control
(dry contacts / 16 or 19 pin plug
•
Start / Stop the pump:
through remote control connector (by setting 15 to 24 V DC
between pin 1-2 on the remote control connector)
C 21
.
•
Selection of the pump
starting mode
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions