GB 04359 - Edition 03 - Dec 11
3/3
B 60
Alcatel Vacuum Technology France - ATH 200 User’s Manual
Remote control plug connection
(dry contacts / 16 pin plug)
Pump working
conditions (with main
power on)
Pump status
Remote control plug
3/4
7/8
9/10
11/12
13/14
Pump running
Close
Close
Close
Close
Close
Pump stopped
Open
Close
Close
Close
Open
Pump r warning
Close
Open
Close
Close
Close
Pump s hazard
Open
Close
Open
Close
Open
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions