Configuration Option Tables
A-10
7110-A2-GB20-00
June 1997
Table A-4.
Data Port Options (2 of 3)
Invert Transmit and Received Data
Possible Settings: Disable, Enable
Default Setting: Disable
Specifies whether the synchronous data port’s transmitted data and received data are
logically inverted before being transmitted or received. This configuration option is
useful for applications where HDLC data is being transported. Inverting the data
ensures that the density requirements for the network interface are met.
Disable – Indicates the transmitted data and received data for this port are not inverted.
Enable – Indicates the transmitted data and received data for this port are inverted.
Send All Ones on Data Port Not Ready
Possible Settings: Both, Disable, DTR, RTS
Default Setting: Both
Specifies the conditions on the data port that determine when valid data is not being
sent from the DTE. When this condition is detected, all ones are sent to the network on
the DS0 channels allocated to the synchronous data port.
Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to the
network.
Disable – Disables the monitoring of interchange circuits from the DTE connected to
the synchronous data port.
DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR is
interrupted, all ones are sent to the network.
RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS is
interrupted, all ones are sent to the network.
Action on Network Yellow Alarm
Possible Settings: Halt, None
Default Setting: Halt
Specifies the action taken on the synchronous data port when a Yellow Alarm is
received on the network interface.
Halt – Stops the transmission of data on the data port and disables the data port when
Yellow Alarms are received on the network interface. When Yellow Alarms are received,
all ones are sent on the Received Data interchange circuit BB (CCITT 104). The
Clear-to-Send interchange circuit CB (CCITT 106) is interrupted.
None – Makes the data port unaffected by Yellow Alarms received on the network
interface.