49
Attachments
About mail notification
The main unit's address appears in the alarm mail as shown below.
Contents of the alarm mail
The following mail will be sent to notify of a trouble occurrence to a registered address when the trouble occurs.
ND400 (192.16
8
.0.250) STATUS REPORT.
DATE: 1-JAN-200
8
12:00:00 GMT+0:00
STATUS: The description of the trouble will be displayed. (Ex. MAIN THERMAL ERROR)
Alarm mail notification
ND400 (192.16
8
.0.250), alarm was occurred.
Alarm date: xx-xxx-xxxx xx:xx:xx GMT xx:xx (Example: 01-JAN-
200
8
GMT+0:00)
Cause of alarm: Displays an event type and a camera channel or
an alarm number (Example: COMMAND ALARM 5CH)
File name of alarm image: The file name of the image attached to
an e-mail.
URL:http://192.16
8
.0.250/
Warning mail notification
Item
Description
DATE
Time and date when the trouble occurred will be displayed.
STATUS
The description of the trouble will be displayed.
HDD capacity warning
*1
: <Anything other than FULL>
NORMAL-HDD CAPACITY REMAINS **%
EVENT-HDD CAPACITY REMAINS **%
COPY-HDD CAPACITY REMAINS **%
** is remaining capacity (%).
:
<FULL>
EVENT-HDD FULL
COPY-HDD FULL
Power outage detection
: POWER LOSS
Recover from a power outage
: POWER RECOVERED
NW camera error detection
: CAM** COMMUNICATION ERROR
** is camera channel.
NW camera error recovery
: CAM** COMMUNICATION RECOVERED
** is camera channel.
NW camera error detection (audio)
: CAM** COMMUNICATION ERROR (AUDIO)
** is camera channel.
NW camera error recovery (audio)
: CAM** COMMUNICATION RECOVERED (AUDIO)
** is camera channel.
HDD smart warning
*2
: Recorder: MAIN-y SMART WARNING
Extension unit: EXTx-y SMART WARNING
x is unit number, y is disk number.
HDD hour meter warning
: Recorder: MAIN-y HOUR METER WARNING
Extension unit: EXTx-y HOUR METER WARNING
x is unit number, y is disk number.
Remove auto links (per HDD)
: Recorder: MAIN-y LOGICALLY REMOVED
Extension unit: EXTx-y LOGICALLY REMOVED
x is unit number, y is disk number.
Remove auto links (per unit)
: Recorder: MAIN LOGICALLY REMOVED
Extension unit: EXTx LOGICALLY REMOVED
x is unit number.
Содержание WJND400 - NETWORK DISK RECORDER
Страница 73: ...4 ...