FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-7
5-1-3 Setting Items and Default Values
Setting item
Setting range / set values
Page
Basic
settings
(BASIC)
HIGH set value (HI.SET)
You can manually set any HIGH set value (upper limit value)
-199.9999 to 199.9999 (mm)
<Default value: 5.0000> 5-11
LOW set value (LO.SET)
You can manually set any LOW set value (lower limit value)
-199.9999 to 199.9999 (mm)
<Default value: 1.0000> 5-12
Hysteresis (HYSTER)
If the judgment value (JUDGE.V) fluctuates near the HIGH
or LOW set value, the judgment output may repeat ON /
OFF and operation may become unstable. Operation can be
stabilized by increasing the hysteresis value.
0.0000 to 199.9999 (mm)
<Default value: 0.0030>
Teaching type (TEACH)
You can set the HIGH set value and LOW set value auto
-
matically.
TCH.1 (1-point teaching) / TCH.2 (2-point teaching) / TCH.3
(3-point teaching)
<Default value: TCH.1>
Tolerance <±> (TOL<±>)
When performing 1-point teaching, you can set a value equal
to the master workpiece judgment value (JUDGE.V) plus a
tolerance as the HIGH set value, and a value equal to the
master workpiece judgment value minus a tolerance as the
LOW set value.
<Default value: 0.1000>
Preset value (PR. VAL)
When performing preset, you can shift (add or subtract) to
any preset value.
-199.9999 to 199.9999 (mm)
<Default value: 0.0000>
Preset data selection
(PR.OBJ)
When using a preset, you can select the data (NORM.V or
JUDGE.V).
NORM.V (normal measured value) / JUDGE.V (judgment
value)
<Default value: NORM.V>
Preset save (PR.SAVE)
You can write preset information to EEPROM by setting pre
-
set save to ON.
The preset ON / OFF state and offset values are saved even
when the power is turned OFF.
OFF (preset save OFF) / ON (preset save ON)
<Default value: OFF>
Measurement direction
(DIRECT)
You can set whether the normal measured value (NORM.V)
and judgment value (JUDGE.V) are displayed normally (plus
direction) or in reverse (minus direction) when the sensor
head spindle is pressed in.
NORMAL (normal) / REVERS (reverse)
<Default value: NORMAL>
Lever ratio (LEVER)
When using a lever for measurement, you can display the
measured value multiplied by the lever ratio as the judgment
value (JUDGE.V).
0.1 to 100.0
<Default value: 1.0>
Response time (SPEED)
You can set the time until the judgment value (JUDGE.V) is
finalized (response time) when the sensor head starts mea
-
surement.
3 (3ms) / 5 (5ms) / 10 (10ms) / 100 (100ms) 500 (500ms) /
1000 (1,000ms)
<Default value: 100>
Output operation (OUTPUT)
You can select the judgment output operation.
N.O. (normal open) / N.C. (normal closed)
<Default value: N.O.>
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...