5-2-5 Tolerance <±> (
)
When performing 1-point teaching, you can set a value equal to the master workpiece judgment
value (JUDGE.V) plus a tolerance as the HIGH set value, and a value equal to the master work-
piece judgment value minus a tolerance as the LOW set value.
HIGH set value
LOW set value
Midpoint of allowed value
When tolerance <±> = 1.000
-1.000
Master workpiece
+1.000
<Reference>
●
The tolerance setting (±) is only valid when 1-point teaching is ON.
●
For the 1-point teaching method, refer to
.
Setting method
Long-press for 2 seconds
: Move through digits
Finalize
: Change value
CALC: Only appears on master unit
Setting
Setting range
Default value
Tolerance (±) (TOL<±>)
0 to 199.9999
0.1000