INSTALLATION AND CONNECTIONS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
3-16
3-6 Connection Diagrams and I/O Circuit Diagrams
3-6-1 Connection Diagrams
●
HG-SC101, HG-SC101-P
(Pink) External input 1
(Violet) External input 2
(Pink / Violet) External input 3
(Blue) 0V
(Brown) + V
(Black) Output 1
(Gray) Analog current output (4 to 20mA)
(Shielded) Analog ground (Note)
(White) Output 2
(Black / Gray) Output 3
Note: Use shielded wire for the analog output.
●
HG-SC111, HG-SC111-P
(Pink) External input 1
(Violet) External input 2
(Pink / Violet) External input 3
(Black) Output 1
(Gray) Analog current output (4 to 20mA)
(Shielded) Analog ground (Note)
(White) Output 2
(Black / Gray) Output 3
Note: Use shielded wire for the analog output.
<Reference>
The
HG-SC111
and
HG-SC111-P
cables do not have +V or 0V. Power is supplied from the con-
nector of the master unit.