FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-9
Setting item
Setting range / set values
Page
Advanced
settings
(ADVANC)
Alarm setting (ALARM)
Alarm delay count
(DELAY)
You can set the delay count until an alarm is output.
1 to 1000
<Default value: 1000> 5-68
Pressure check
(PRS.CHK)
You can turn the pressure check ON / OFF.
ON (check ON) / OFF (check OFF)
<Regular type default value: ON>
<Air-driven type default value: OFF>
Pressure check set value
(PRS.SET)
When the pressure check is set to ON, you can set the pres-
sure check set value.
-199.9999 to 199.9999 (mm)
<Regular 10 mm type, air-driven type default value: 10.0000>
<Regular 32 mm type default value: 32.0000>
<Regular 50 mm type default value: 50.0000>
Catch check
(CAT.CHK)
You can turn the catch check ON / OFF.
OFF (check OFF) / ON (check ON)
<Default value: OFF>
Number of connected
controllers check
(CON.CHK)
(Master unit only)
When controllers are connected to the master unit, you can check if
the number connected has changed when the power is turned ON.
OFF (check OFF) / ON (check ON)
<Default value: OFF>
Calculation
settings
(CALC)
(Master
unit only)
Calculation mode (MODE)
You can perform calculation processing based on the
measured values of each of the connected controllers and
display the judgment result on the master unit's display or
output the judgment result from the master unit.
NO.CALC (no calculation) / CALC (calculate)
<Default value: NO.CALC>
Calculation application se-
lection (APPLI)
When calculation mode is set to "CALC", you can select the
application that is used for calculation.
MAX (maximum value) / MIN (minimum value) / FLAT (flat
-
ness) / AVERAG (average value) / STAND (standard differ
-
ence) / TORSIN (torsion) / CURVEA (curvature) / THICK
(thickness)
<Default value: MAX>
Copy
settings
(
COPY)
Copy select individual
(
CPY.SEL
)
(
Master unit only
)
You can select individual items to be copied.
Copy select all
(
CHK.ALL
)
(
Master unit only
)
You can select all items for copying.
YES / NO
<Default value: YES>
Copy execution
(
CPY.EXE
)
(
Master unit only
)
You can execute copying of individually selected settings or
all settings from the master unit to the slave units.
YES / NO
<Default value: YES>
Copy lock
(
LOCK
)
(Slave unit only)
You can prohibit copying from the master unit.
OFF (lock OFF) / ON (lock ON)
<Default value: OFF> 5-91
Bank
settings
(
BANK
)
Bank save selection
(BNK.DAT)
You can select the settings in a bank that are read by a bank
read.
THRS (HIGH set value, LOW set value) / THRS.PR (HIGH
set value, LOW set value, preset value) / ALL (all)
<Default value: THRS>
Calibration
settings
(
CALIB
)
Calibration selection
(
CAL.SEL
)
You can perform zero-point adjustment and span adjustment
when a sensor head is replaced to reduce installation error.
DEFAUL (default) / USER (user settings)
<Default value: DEFAUL>
During
user
set
tings
Acquired value 1
(
CL.SET1
)
Move the spindle to the zero point for calibration and acquire
the measured value.
Acquired value 2
(
CL.SET2
)
Move the spindle to the target point for span adjustment and
acquire the measured value.
Adjustment value 2
(
AJ.VAL2
)
Enter a number for the target value.
-199.9999 to 199.9999 (mm)
<Default value: 10.000>
Initialization
(
RESET
)
Initialization
(
RESET
)
You can return the controller settings to the factory default
state.
YES / NO
<Default value: YES>
Maintenance
(
MAINTE
)
Total stroke operation log
(
SUM .REC
)
You can display the sensor head operation log and other in
-
formation.
Maximum peak value
(
MAX. VAL
)
Maximum peak value opera-
tion log
(
MAX. REC
)
Over stroke log
(
OVR. NUM
)
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...