BASIC OPERATION
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
4-5
4-2 Explanation of Modes
4-2-1 Display Switching Mode
<Overview>
You can change the display of the digital display / SUB (green) as needed for the task.
Using the display switching function, you can display the actual measured value (spindle posi-
tion) and a judgment value such as a calculation result at the same time for comparison. This
makes it easy to check the state of sensor head measurement.
<Settings>
1. Normal measured value (default value)
6. Sensor head measured value
2. Calculated value (Note)
5. HIGH set value
3. Label
4. LOW set value
Name
Digital display
SUB (green)
Description
Factory
default state
1
Normal measured
value
Shows the normal measured value.
• When displayed while using the hold function, you
can check internal measured values that are not held.
Default state
2
Calculated value
(Note)
Shows the calculated value.
• When displayed while using the calculation function
and hold function, you can check calculation results
that are not held.
–
3
Label
You can view and set any values or characters.
• This saves you the trouble of attaching sensor num-
ber and other labels on the controller.
–
4
LOW set value
Shows the LOW set value.
•
You can check the judgment value and lower limit
value at the same time.
–
5
HIGH set value
Shows the HIGH set value.
•
You can check the judgment value and upper limit
value at the same time.
–
6
Sensor head mea-
sured value
Shows the measured value (spindle position) from the
sensor head.
•
You can display this while using a preset or the cali
-
bration function to check the actual pre-correction
measured value (spindle position).
–
Note: Calculation function settings are configured on the master unit. When a setting other than "STAND" (stan
-
dard difference) is selected for the calculation function, "CALC" appears only on the master unit. When the
"STAND" (standard difference) setting is selected for the calculation function, "CALC" appears on the slave
units but not on the master unit. When the calculation function is not used, this does not appear on either
the master unit or the slave units.
<Reference>
●
"HEAD.V" (Head Value) is the measured value (spindle position) from the sensor head.
● "NORM. V" (Normal Value) reflects the preset, measurement direction, lever ratio, and calibra
-
tion function.
●
The judgment value that appears in the digital display / MAIN (white) triggers judgment output
ON / OFF based on the LOW set value and the HIGH set value. Analog output is also output
based on the judgment value.
For the data flow, refer to
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...