FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-12
5-2-2 LOW Set Value (
)
You can manually set any LOW set value (lower limit value).
If the judgment value (JUDGE.V) is under the LOW set value, a LOW judgment is output.
HIGH set value
LOW set value
Judgment value
<Reference>
●
Always set a LOW set value that is lower than the HIGH set value.
● You can have the LOW set value always appear in the digital display / SUB (green).
For details, refer to
“4-2-1 Display Switching Mode”
.
● You can set the HIGH set value and LOW set value by teaching.
For details, refer to
Setting method
Long-press for 2 seconds
: Move through digits
: Change value
Finalize
CALC: Only appears on master unit
Setting item
Setting range
Default value
LOW set value (LO.SET)
-199.9999 to 199.9999 (mm)
1.0000