FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-50
<Reference>
●
When self peak hold or self bottom hold is selected, external trigger input is invalid.
●
When a sensor head not connected error or pressure alarm / error is cleared, the same action
as a reset takes place.
■
Self Peak Hold (Trigger mode: One-shot)
After the end of self trigger, the peak value during the sampling interval (the interval from the
end to the start of self trigger) is held as the judgment value (JUDGE.V).
When self trigger starts, the next sampling interval starts.
Self trigger starts when the value rises above (falls below) the self trigger level.
Self trigger ends when the value falls below (rises above) the self trigger level.
Timing chart
Due to RESET,
indeterminate until hold
Self
trigger
start
Self
trigger
end
Self trigger start
Self trigger
end
External
reset
Due to RESET, NORM.V is
indeterminate during response time
Sampling
interval
Sampling
interval
Sampling interval
Indeterminate when
power is turned ON
Self trigger
level
Hold
interval
Hold
interval
Hold
interval
HIGH set value
Normal measured value (NORM.V)*
ON
ON
TRIG
indicator
HOLD
indicator
LOW set value
OFF
OFF
Judgment value (JUDGE.V)
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1.
When the power is turned ON, the indeterminate state is held until self trigger ends.
2.
When self trigger ends, the maximum normal measured value (NORM.V) that occurs during
the sampling interval is held as the judgment value (JUDGE.V).
3.
The previous value is held from the start of self trigger to the end (sampling interval).
4.
If the reset input turns ON, the indeterminate state is held. If within the sampling interval, the
sampling interval ends.
5.
Judgment output outputs the judgment result based on the output setting.
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...