FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-81
■
Average Value (
)
This application calculates the average value of the measured values of the master unit and
slave units.
Master
unit
Slave
unit 2
Slave
unit 1
([Master unit] + [Slave unit 1] + ... + [Slave unit n]) ÷
(1+n) is calculated value of master unit.
"n" is the number of slave units
• None of the connected slave units output the judgment result. (Always OFF)
• All sensor head indicators show the judgment result of the master unit.
• The response time for judgment output is the response time setting on the master unit and
slave units plus 3ms.
■
Standard Difference (
)
This application calculates the difference between the measured value of each slave unit and
the master unit.
With this application, each slave unit outputs the judgment result.
Master
unit
Slave
unit 2
Slave
unit 1
(Measured value of "slave unit 2" - Measured value of
"master unit") is calculated value of master unit.
• The master unit performs judgment as a separate unit that does not perform calculation.
• The hold function cannot be used on the master unit.
• The response time for judgment output is the response time setting on the master unit and
slave units plus 3ms.
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...