INSTALLATION AND CONNECTIONS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
3-9
3-4-3 Connecting the Air Tube (Air-Driven Type Only)
1.
While loosening the air tube clamp, slide it from the tip of the air tube and then release it
when it reaches halfway through the tube.
2.
Insert the tip of the air tube until it reaches the root of the joint on the sensor head.
3.
Move the air tube clamp and secure the tip of the air tube.
ø4mm air tube
Air tube clamp
(Accessory)
3-4-4 Disconnecting the Air Tube (Air-Driven Type Only)
1.
While loosening the air tube clamp, move it halfway through the air tube.
2.
Grasp the sensor head and pull out the air tube.
Note: Take care not to lose the air tube clamp.