Slim Multi-Sensor TSM02
The slim multi-sensor TSM02 has PIR, door/window, temperature and
illumination, 4 sensors function in one, based on Z-Wave
TM
technology.
Z-Wave
TM
is a wireless communication protocol designed for home
automation, specifically to remotely control applications in residential
and light commercial environments. The technology uses a low-power
RF radio embedded or retrofitted into home electronics devices and
systems, such as lighting, home access control, entertainment systems
and household appliances.
This device is one component of the Z-Wave
TM
sensor system and is
designed to work with all other Z-Wave
TM
enabled devices in a home
control network. The device adopt the Z-Wave
TM
400 series chip, when
your Z-Wave
TM
network system is all made by Z-Wave
TM
400 series
devices. The network system will have the advantages as below.
•
Concurrent multi-channel support reduces external interference.
•
Better RF range, improve about 10 meters in indoor.
•
Support 100 Kbps transmit speed, speed up communication.
Adding to Z-Wave
TM
Network
There are two tamper keys in the device, one is in the back side,
another is in the front side. They have the same function. Both of them
can inclusion, exclusion, reset or association from Z-Wave
TM
network.
In the first time, add the device into the Z-Wave
TM
network. First, make
sure the primary controller is in the inclusion mode. And then power on
the device, just take out the insulation Mylar in the back side of the
device. The device will auto start the NWI (Network Wide Inclusion)
mode. And it should be included in 5 seconds. You will see the LED
light ON one second.
Function
Description
Inclusion
1. Have Z-Wave
TM
Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter inclusion mode.
3. After inclusion successful, the device will wake to
receive the setting command from Z-Wave
TM
Controller about 20 seconds.
Exclusion
1. Have Z-Wave
TM
Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter exclusion mode.
Node ID has been excluded.
Reset
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4
th
pressed, and the LED will turn ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.