FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-83
■
Curvature (
)
This function calculates the curvature from measured values at three locations on the measured
object.
Calculated value = (Measured value of master unit + Measured value of slave unit 2)
÷ 2 - Measured value of slave unit 1
Master
unit
Slave
unit 2
Slave
unit 1
• The two slave units closest to the master unit do not output a judgment result. (Always OFF)
If three or more slave units are connected, the 3rd and subsequent slave units perform
normal judgment without calculation.
• The sensor head indicators of the two slave units closest to the master unit show the judg-
ment result of the master unit.
• The response time for judgment output from the master unit is the response time setting
on the master unit and slave units plus 3ms.
<Reference>
This application can only be selected when at least two slave units are connected.