5-2-4 Teaching Types (
)
You can set the HIGH set value and LOW set value automatically.
For the teaching method, you can select from "1-point teaching", "2-point teaching", or "3-point
teaching".
Teaching type
Function
Factory
default state
1-point teaching
You can use a master workpiece to automatically set upper and lower
limit values.
Use this method when you want to judge workpieces by a ± tolerance.
+1.0000
HIGH set value
Judgment value
LOW set value
-1.0000
Tolerance
Tolerance
*: When the tolerance (±) is set to 1.0000
Default state
2-point teaching
You can use two workpieces to automatically set upper and lower limit
values.
Use this method when you want to judge workpieces within an upper limit
and lower limit range.
HIGH set value
LOW set value
―
3-point teaching
You can use a good workpiece, a HIGH-side defective workpiece, and a
LOW-side defective workpiece to automatically set upper and lower limit
values.
Use this method when you want to judge workpieces within a range that
takes the intermediate values between good and defective workpieces as
upper and lower limits.
HIGH set value
LOW set value
Lowest value
Highest value
Median value
―
<Reference>
For teaching type, refer to
Содержание HG-S Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Страница 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Страница 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Страница 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Страница 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Страница 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Страница 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Страница 198: ... MEMO ...