10 – 89
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
10
Appendix
Appendix
Commissioning report
AQUAREA – COMMISSIONING R3 NOV13
Setting Range
Recommended
settings
Settings
1
Outdoor Ambient Low
To_Lo
-15 ~ 15
5
SET-1
2
Outdoor Ambient High
To_Hi
-15 ~ 15
15
SET-2
3
Water Temp @ Low
Tw_Hi
25 ~ 55
55*
SET-3
4
Water Temp @ High
Tw_Lo
25 ~ 55
45
SET-4
5
5 ~ 35
20
SET-5
6
-15 ~ 20
-5
SET-6
7
5 ~ 20
SET-7
8
40 ~ 75
50 / 60**
SET-8
9
-5 ~ 5
0
SET-9
10
Yes / No
SET-10
11
3 / 6 / 9 kW
†
SET-11
12
Yes / No
Yes
SET-12
13
Yes / No
SET-13
14
Yes / No
No
SET-14
15
Yes / No
No
SET-15
16
0.5 ~ 10 hrs
01:00
SET-16
17
0:05 ~ 1:35 hrs
00:30
SET-17
18
Yes / No
SET-18
19
0:20 ~ 1:35 hrs
00:25
SET-19
20
Yes / No
Yes
SET-20
21
SET-21
22
40 ~ 75
65
SET-22
23
0.05 ~ 1:00 hr
01:00
SET-23
* Temp must be low er w ith underfloor heating
Heating Interval
Heating Priority
Solar Priority
Tank Connection
External Room Controller
Water Temp Thermo Shift:
Sanitary Tank Set Temp
Water Set Temp during Cool Mode
Outdoor Ambient Set Temp: Heater Operation:
Outdoor Ambient Set Temp: Heating OFF
† Backup Heater options vary dependant on model
** Sanitary tank temp w ill be higher for HT systems
Sterilization Time/Day
Sterilization Temperature Set
Settings
Press
SET
for 4 Seconds to Access Settings
Sterilization Continue Time
Press
SET
and
CHECK
for 4 Seconds
Tank Interval
Booster Delay
Sterizaltion
Backup Heater Capacity
Water System Freeze Protection
Booster Heater Function Activate
Timers
1
1/0 T H Q
2
1/0 T H Q
3
1/0 T H Q
4
1/0 T H Q
5
1/0 T H Q
6
1/0 T H Q
Monday
MON_1
M 1-0_1
M T _1
M H_1
M Q_1
MON_2
M 1-0_2
M T _2
M H_2
M Q_2
MON_3
M 1-0_3
M T _3
M H_3
M Q_3
MON_4
M 1-0_4
M T _4
M H_4
M Q_4
MON_5
M 1-0_5
M T _5
M H_5
M Q_5
MON_6
M 1-0_6
M T _6
M H_6
M Q_6
Tuesday
TUE_1
T U1-0_1 T UT _1
T UH_1
T UQ_1
TUE_2
T U1-0_2 T UT _2
T UH_2
T UQ_2
TUE_3
T U1-0_3 T UT _3
T UH_3
T UQ_3
TUE_4
T U1-0_4 T UT _4
T UH_4
T UQ_4
TUE_5
T U1-0_5 T UT _5
T UH_5
T UQ_5
TUE_6
T U1-0_6 T UT _6
T UH_6
T UQ_6
Wednesday
WED_1
W1-0_1
WT _1
WH_1
WQ_1
WED_2
W1-0_2
WT _2
WH_2
WQ_2
WED_3
W1-0_3
WT _3
WH_3
WQ_3
WED_4
W1-0_4
WT _4
WH_4
WQ_4
WED_5
W1-0_5
WT _5
WH_5
WQ_5
WED_6
W1-0_6
WT _6
WH_6
WQ_6
Thursday
THU_1
T H1-0_1 T HT _1
T HH_1
T HQ_1
THU_2
T H1-0_2 T HT _2
T HH_2
T HQ_2
THU_3
T H1-0_3 T HT _3
T HH_3
T HQ_3
THU_4
T H1-0_4 T HT _4
T HH_4
T HQ_4
THU_5
T H1-0_5 T HT _5
T HH_5
T HQ_5
THU_6
T H1-0_6 T HT _6
T HH_6
T HQ_6
Friday
FRI_1
F1-0_1
FT _1
FH_1
FQ_1
FRI_2
F1-0_2
FT _2
FH_2
FQ_2
FRI_3
F1-0_3
FT _3
FH_3
FQ_3
FRI_4
F1-0_4
FT _4
FH_4
FQ_4
FRI_5
F1-0_5
FT _5
FH_5
FQ_5
FRI_6
F1-0_6
FT _6
FH_6
FQ_6
Saturday
SAT_1
SA 1-0_1 SA T _1
SA H_1
SA Q_1
SAT_2
SA 1-0_2 SA T _2
SA H_2
SA Q_2
SAT_3
SA 1-0_3 SA T _3
SA H_3
SA Q_3
SAT_4
SA 1-0_4 SA T _4
SA H_4
SA Q_4
SAT_5
SA 1-0_5 SA T _5
SA H_5
SA Q_5
SAT_6
SA 1-0_6 SA T _6
SA H_6
SA Q_6
Sunday
SUN_1
SU1-0_1 SUT _1
SUH_1
SUQ_1
SUN_2
SU1-0_2 SUT _2
SUH_2
SUQ_2
SUN_3
SU1-0_3 SUT _3
SUH_3
SUQ_3
SUN_4
SU1-0_4 SUT _4
SUH_4
SUQ_4
SUN_5
SU1-0_5 SUT _5
SUH_5
SUQ_5
SUN_6
SU1-0_6 SUT _6
SUH_6
SUQ_6
Key:
1/0:
On / Off
T:
Tank On
H:
Heating On
Q:
Quiet Mode On
Heating Mode
Compressor Frequency :
Tank Mode
Compressor Frequency :
Comments:
Customer Signature :
Commssioned by :
Print :
The above settings have been explained to me, including w eather compensator, and understand w hat an Air to Water Heat Pump is.
Date :
COMMENTS
CUSTOMER SIGNATURE
COMMISSIONED BY
DATE
PASS / FAIL
Commissioned
Status:
COMP Hz (T)
COMP Hz (H)
Performance
Check :
Water Out :
Water Out :
OD Temp :
OD Temp :
OD TEMP (T)
OD TEMP (H)
Water In :
Water In :
Delta T :
Delta T :
DELTA T (T)
DELTA T (H)
H2O IN (T)
H2O IN (H)
H2O OUT (T)
H2O OUT (H)
NO:
Steps 14 ~ 23 skipped
YES:
Steps 16 ~ 17 skipped
NO:
Step 19 skipped
NO:
Step 21 ~ 23 skipped
IMPORTANT NOTE:
Please carryout all steps during commissioning.
Failure to complete steps may result in lack of
functionality or poor performance
NO
NO
NO
NO
NO
NO
NO
FAIL
Water
temp.
Outdoor
temp.
Shift
value