9 – 78
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
Commissioning
Programming
Displays | Button assignment
9.5 Programming
Button assignment
17
Operation button (ON / OFF)
18
Operating mode selection button
Use this button to select the operating
mode required .
19
System status buttons
These buttons are used for a series of
status queries . Proceed as follows:
➤
Press the CHECK button for 5 seconds
to switch to Status mode .
➤
Press the UP or DOWN button to open
the following values:
1 . Compressor operating frequency
2 . Error code
3 . Water inlet temperature
4 . Water tank temperature
➤
Press the CANCEL button or wait
30 seconds to quit Status mode .
20
Service button
This button takes you to menu items Sr:01
for pump down mode and Sr:02 for
circulation pump . You can toggle
between the two menu items using
the SEARCH arrow buttons .
21
Button for enabling the additional elec-
tric heater for the heat pump . The addition-
al electric heater can only be user if this
button is pushed . Note: If this button is not
pressed, the additional electric heater for
the heat pump is only used for:
• Defrosting
• Device startup
• Frost protection mode
22
Emergency heating mode button
This button allows the device to be operated
in emergency heating mode with the
additional electric heater for the heat
pump, e .g . if the heat pump is defective .
Press the ON / OFF button to switch off
emergency heating mode .
23
Error reset button
24
Quiet mode button
25
System programming buttons
These buttons are used to set temperature
values .
26
Timer programming buttons
These buttons are used to set the time and
the weekly timer .
1
Operation LED
2
Display of external room
thermostat
3
Display of solar installation
4
Display of operation of additional
electric heater for heat pump
and emergency heating mode
(ON / OFF)
5
Display for quiet mode
(ON / OFF)
6
Hot-water tank operation
display (ON / OFF)
7
Cooling operation display (ON /
OFF) (The operator control
panel of the SDF models has
no display for cooling mode)
8
Heating operation display
(ON / OFF)
9
Display of timer setting and time
10
Display of outside temperature
11
Display of water outlet
temperature
12
Display of additional electric
heater for the heat pump and
the electric immersion heater
for the hot-water tank
(ON / OFF)
13
Display for defrosting (ON / OFF)
14
Display for system program-
ming (ON / OFF)
15
Display for system status
(ON / OFF)
16
Display for service (ON / OFF)
SET
SELECT
SETTING
OFF/ON
WATER OUTLET
TIMER
OUTDOOR
ACTUAL
HEATER
SETTING
STATUS
SERVICE
DEFROST
HEAT
COOL
TANK
QUIET
HEATER
FORCE
BOOSTER
STATUS
SEARCH
CANCEL
CLOCK
FORCE SERVICE
ERROR
RESET
OFF/ON
QUIET
HEATER
MODE
CHECK
TIMER
OPERATION
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
16
18
17
19
23 22
21 20
25 24
26
Displays
Note
As the same operator control
panel is used for different
devices, some functions may
not apply for your device .