6 – 38
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
Hydraulic installation for monobloc systems
➤
Proceed as follows to install a condensate pipe to drain condensate
formed in the monobloc unit during operation:
➤
Use a drain hose with an internal diameter of 15 mm .
➤
Connect the drain hose to the monobloc unit .
➤
Lay the drain hose with a downward slope . For long drain hoses,
use a metal support if necessary to prevent the hose bending .
➤
Lay the drain hose so that closures or blockages cannot occur .
➤
Do not insert the drain hose in a waste water system from which
aggressive gasses such as ammonia gas, sulphur gas etc . can
escape .
1
PRV release point is from the pri-
mary heating circuit and may con-
tain additives and antifreeze which
needs to be disposed of correctly .
1
Warning!
If the device is used in areas
where the temperature can re-
main below zero for 2 to 3 days,
condensate pipes should not be
used, as the condensate could
freeze, which can cause mal-
functions .