ItThresh
(NV Parameter, Integer) i82
Units
% (Percentage) of drive peak current
Range
0 to 100 (Actual upper limit depends on Model)
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected motor
and& drive.
Purpose
ItThresh
sets the desired maximum continuous output current, as a
percentage of Ipeak, before the I*t thermal protection faults the drive.
Guidelines
ItThresh
, in conjunction with
ItF0
, specifies the thermal
protection fault for the drive. The actual I*t fault threshold may be
lowered if the heat sink temperature (
HSTemp
) gets too high, see
ItThreshA
.
Note:
The maximum value for
ItThresh
is limited to protect the
drive’s power electronics.