Problem & Status
Display
Possible Cause
Action
Bus Over Voltage
Detected By DSP
(Blinking A)
Actual bus over voltages are usually, but not always,
detected and displayed as a blinking 7 fault, see that
entry for more information.
Drive improperly set up in
the factory.
Contact distributor.
Return to factory.
Aux5V Supply
Fault (Blinking b)
Short circuited wiring on
the output.
Check for short.
Load exceeds the current
rating of this supply.
Reduce load.
Processor Throughput
Fault (Solid E)
Drive hardware failure.
Cycle control power.
Drive software bug.
Cycle control power.
Power Up Self Test Failure
(Blinking E)
Internal drive software
error.
See
ExtFault
for further
information about the
exact failure.
The drive control power
must be cycled to clear
this fault.
Bus Voltage Fault
(Alternating E, 1)
Motor power bus voltage
dropped below
VBusThresh
.
Check the measured bus
voltage
VBus
and the fault
threshold
VBusThresh
.
Ambient Temperature Too
Low Fault
(Alternating E, 2)
Ambient temperature is
below drive specification.
Raise ambient temperature
above 0
°
C.
Drive’s internal
temperature sensor has a
wiring problem.
Contact distributor. Return
to factory.