PosErrorMax
(NV Parameter, Integer) i285
Units
Counts (same units as position feedback)
Range
0 to 294,912,000 (4500 revs)
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value to 4096.
Purpose
PosErrorMax
sets the maximum value in position feed back counts
for the position loop following error fault.
Guidelines
The following error fault compares
PosError
with the
PosError
predicted from
EncFreq
and
Kvff
and if the magnitude of the
difference is larger than
PosErrorMax
continuously for longer than
1 second or statistically larger over half the time the drive will
following error fault (“
F 1
”). If you have mapped one of the BDIO
outputs as
PosErrorWarning
, then this output will be activated
and the following error fault (“
F 1
”) will be disabled.