Appendix D Troubleshooting and
Fault Diagnostic Guide
Introduction
The following table of problems, causes and appropriate actions
complements the list of SC900 fault codes found in Section 7
(page 7-56).
Problem & Status
Display
Possible Cause
Action
Velocity Feedback
Over Speed Fault
(Blinking 1)
Loose or open circuit wiring to the
resolver feedback connector J3.
Check connections.
Tighten TB screws on
J3.
VelFB > 1.5 * [Max Of (|VelLmtLo|
or |VelLmtHi |)]
or
VelFB > 21,000 RPM
Limit
VelCmd
appropriately.
Note:
For Encoder
velocity feedback
(
CommSrc
= 1 or 2)
check that EncIn is set
properly to correctly
scale the
VelFB
units.
Motor Over
Temperature Fault
(Blinking 2)
Loose or open circuit wiring to motor
PTC thermal sensor (J3-8 and J3-9).
Check connections.
Tighten TB screws on
J3-8 and J3-9.
High ambient temperature at motor.
Lower ambient
temperature.
Insufficient motor heat sinking from
motor mounting.
Increase motor
mounting heat sinking.
Operating above the motor’s
continuous current rating.
Operate within
continuous torque
rating.
Inoperative motor cooling fan.
Return to factory for fan
replacement.
MA930 Manual