Examples
Read FaultCode from the Drive.
FaultCode is an Integer Variable (D). FaultCode’s Identifier
Number is 000E. For this example, let’s assume the value of
FaultCode is 3.
Message:
^A^B FF 05 0005 D 000E D2
Response:
^A^B FF 00 0008 03 00 00 00 3A
Read Velocity from the Drive.
Velocity is a Floating Point Variable (C). Velocity’s Identifier
Number is 0006. For this example, let’s assume the value of
Velocity is 1000.1.
Message:
^A^B FF 05 0005 C 0006 C2
Response:
^A^B FF 00 0008 66067A44 69
Write New Value for ILmtPlus to the Drive
IlmtPlus is an Integer Variable (D). IlmtPlus’s Identifier Number
is 0005. For this example, let’s write a new value of 50 percent
(decimal 50 = 32 hex).
Message:
^A^B FF 06 000D D 0005 32 00 00 00 57
Response:
^A^B FF 00 0002 00 11
Write New Value for AccelLmt
AccelLmt is a Floating Point Variable (C). AccelLmt’s Identifier
Number is 276. This corresponds to 0114 in hexadecimal. For
this example, let’s write a new value of 10,000.
Message:
^A^B FF 06 000D C 0114 00401C46 74
Response:
^A^B FF 00 0002 00 11