DM1Map
(NV Parameter, Integer) i7
Range
0 to 65,537
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value to 9 (
IFB
).
Purpose
DM1Map
selects the signal sent to the DAC Monitor 1 output on
J4-3.
Guidelines
Monitor #
Mnemonic
Monitor #
Mnemonic
0
AnalogOut1
16
IR
1
VelFB
17
IS
2
VelCmdA
18
IT
3
VelErr
19
VR
4
FVelErr
20
VS
5
Position*
21
VT
6
PosError*
22
VBus
7
PosCommand*
23
ResPos*
8
ICmd
24
Non-Trq Icmd
9
IFB
25
Non-Trq IFB
10
AnalogIn
26
Trq VCmd
11
EncFreq
27
Non-Trq Vcmd
12
EncPos*
28
VelCmd
13
ItFilt
65536
Clamp Off†
14
HSTemp
65537
Clamp On†
15
Comm Ang*
* - Will wrap around when the signal exceeds the output voltage
range.
† - The value of the selected signal does not change.
See also
DM1Gain, DM1F0
, and
DM1Out
MA930 Manual