ItF0
(NV Parameter, Float) f11
Units
Hertz
Range
Lower limit set by Model
Upper limit > 10
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value based on the selected drive.
Purpose
ItF0
specifies the corner frequency of the low-pass filter
implementing the I*t drive thermal protection circuit.
Guidelines
ItF0
, in conjunction with
ItThresh
specifies the thermal
protection circuit for the drive.
ItF0
is the corner frequency of a
low-pass filter which processes an estimate of the drive’s power
dissipation. Increasing
ItF0
makes the response more sensitive to
over-current conditions.
Note:
The minimum frequency for
ItF0
(slowest to fault) is limited
to protect the drive’s power electronics.
MA930 Manual
7 - 73