DM1Gain
(NV Parameter, Float) f21
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected motor and
drive.
Purpose
Sets the multiplicative scale factor applied to the
DM1Map
selected
signal before outputting on DAC Monitor 1 (J4-3).
Guidelines
Changing
DM1Map
changes
DM1Gain
’s value unless
DM1Map
changes to a signal with identical units, such as
VelCmdA
to
VelFB
(
DM1Map
= 1 to 2). Set
DM1Gain
to keep the signal in the DAC
Monitor
±
5 volt range. Below lists units when
DM1Gain
= 1.
Monitor#
Scale Factor
Monitor#
Scale Factor
0
No effect
15
1 v/Cycle
1
1 v/kRPM
16
1 v/Amp
2
1 v/kRPM
17
1 v/Amp
3
1 v/kRPM
18
1 v/Amp
4
1 v/kRPM
19
1 v/100%
5
1 v/Rev
20
1 v/100%
6
1 v/Rev
21
1 v/100%
7
1 v/Rev
22
1 v/v
8
1 v/Amp
23
1 v/Rev
9
1 v/Amp
24
1 v/Amp
10
1 v/v
25
1 v/Amp
11
1 v/Hz
26
1 v/100%
12
10 v/4096
27
1 v/100%
13
1 v/100%
28
1 v/kRPM
14
1 v/
°
C
See also
DM1Map, DM1F0
, and
DM1Out
.
MA930 Manual
7 - 39