EncMode
(NV Parameter, Integer) i71
Range
0, 1, 2, or 3
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value to 0.
Purpose
EncMode
specifies the type of digital command expected at the
incremental position command port.
Guidelines
BlkType
= 2 uses the incremental position command port (J4-21,
J4-22, J4-23, J4-24) for its position command.
Value of
EncMode
Description
0
Selects quadrature encoder pulses
1
Selects step-and-direction input signals
2
Selects up/down count input signals
3
Ignores input signal,
EncPos
value held
7 - 52